Non-destructive testing(NDT) Equipments

coating thickness gauge

attachable probe

Features

  • It meets the standards of ISO-2178 and ISO-2360 as well as DIN, ASTM and BS.

  • The F probes measure the thickness of non-magnetic materials.Often used to measure the thickness of galvanizing layer, lacquer layer, porcelain enamel layer, phosphide layer, copper tile, aluminum tile, some alloy tile, paper.
  • The N probes measure the thickness of non-magnetic coating on non-magnetic metals.It is used on anodizing, varnish, paint, enamel, plastic coatings, and powder, etc.applied to aluminum, brass, non-magnetic stainless steel, etc.
  • Automatic Substrate Recognition.
  • Two measurement modes: Single and Continuous.
  • MetricImperial conversion.


  • Model

    NTCA1250

    Display

    4 digits, 10mm LCD

    Range

    0~1250 µm [0~50mil]

    Resolution

    0.1µm [0~99.9µm], 1µm [over 100µm]

    Accuracy

    ±1~3%n or 2.5 µm or 0.01 mil [whichever is greater]

    PC Interface

    with RS-232c interface

    Power Supply

    4 x 1.5 AAA [UM-4] BATTERY

    Operating Condition

    Temp. 0 to 50 °C, Humidity <80%

    Dimension

    126 x 65 x 27 mm

    Weight

    90g [not including batteries]